Aisle Pressure Management

Over the past few decades, Aisle Containment setups have helped Data Center Operators reduce TCO by improving cooling efficiency and limiting cold and hot air mixing.  By limiting airflow draw to perforated tiles instead of free delivery sources, containment aisles foster competition among assets by constraining air supply. This constraint subtly shifts the air pressure in a containment aisle, taxing on-board server fans and creating thermally imbalanced conditions. With AdaptivCOOL Aisle Pressure Management (APM), turbulent airflow and pressure conditions can be mitigated with an airflow control solution automated to respond to pressure and temperature changes or cooling unit failures. APM adds true N+1 redundancy to mission-critical facilities and has demonstrated efficacy in increasing capacity, supplying uninterrupted cooling during CRAC outages and reducing TCO through energy savings.


Why Leaders in Containment Design turn to APM:
  • APM balances airflow pressure in containment aisles in real-time
  • APM affords an airflow redundancy measure (True N+1) in the event of a thermal spike or cooling failure
  • APM reduces TCO and improves cooling efficiency in the Data Center
  • APM can be upgraded to a comprehensive, facility-specific software control system



  • Responsive Fan Tray Tile

    http://www.degreec.com/images/startpage/request_more_info_button_blue_350x50.png

     

    Product Downloads


    http://www.adaptivcool.com/images/apply_f2.png Aisle Pressure Management Brochure 

    http://www.adaptivcool.com/images/apply_f2.png Case Studies

     

     

     

    Solution Benefits


    http://www.adaptivcool.com/images/bullet_thermometer.png  Matches airflow to IT load and pressure conditions in contained aisles

    http://www.adaptivcool.com/images/bullet_24-7.png  Built-in automation to compensate for real-time CRAC/CRAH failures 


    http://www.adaptivcool.com/images/bullet_uptime.png Average IT Capacity Gains of 30%

    http://www.adaptivcool.com/images/bullet_pc.png  Simple, user-friendly inerface for easy collaboration on any device

     

    Technical Features


    http://www.adaptivcool.com/images/bullet_thermometer.png  Interpolates real-time airflow requirements based on data from a network of temperature and pressure sensors and facility cooling assets

    http://www.adaptivcool.com/images/bullet_airflow.png  Airflow control infrastructure dynamically supplies as much as 1200 CFM of airflow or whatever amount is required based on thermal and pressure conditions

    http://www.adaptivcool.com/images/bullet_24-7.png  Environmental monitoring and cooling asset management services available!

    http://www.adaptivcool.com/images/bullet_pc.png  Integrates with any Building Management System or DCIM console